The Effects of the Rountine Meatal Care with 10% Betadine on the Reduction of Catheter-Associated Urinary Tract Infection
Phil Whan Kim, Yeong Kyeong Kim
Journal of Korean Academy of Nursing 1999;29(3):614-624.
DOI: https://doi.org/10.4040/jkan.1999.29.3.614
Published online: March 29, 2017

Ulsan Hospital, Korea.

Department of Nursing, Pusan Catholic College, Korea.

Copyright © 1999 Korean Society of Nursing Science

  • 10 Views
  • 0 Download
prev next
  • The purpose of this study is to determine the effectiveness of routine meatal care on the reduction of catheter-associated urinary tract infection(UTI). The study was carried out on 30 patients with foley catheters in an intensive care unit of a general hospital from September 30 to April 1, 1998, Participants were both male and female. Data were collected from each patients by urinary specimen obtained with aseptic collection technique at the 3rd and the 7th day of the experiment, after giving daily meatal care with 10% betadine for periods ranging from 1st to 7th day to the experimental group but not to the control group. The results are as follows: 1. The rate of urinary tract infection within the experimental group was 0.0%, at the 3rd day of the experiment and 20.0% at the 7th day, but that of the control group was 20.0%at the 3rd day and 7% at the 7th day. There was a significant difference in urinary tract infection rate between the two groups at the 3rd day but no significant difference at the 7th day. 2. In the control group, the rate of UTI was 0.7% for male and 13.3% for female at the 3rd day, and 6.7% for male and 40% for female at the 7th day. In the experimental group, the rate of UTI was 6.7% for male and 0.0%for female at the 3rd day and 13.3% for male and 20% for female at the 3rd day and 13.3% for male and 20% for female at the 7th day of experiment. There was a no significant difference between male and female. 3. By comparing the rate of UTI to the length of time the urinary catheter was in place, the linger the catheter was in place the more significant was the rate of UTI. 4. Microorganisms isolated in the control group were bacteria for 7 cases and fungus for 3 cases but in the experimental group, only 2 cases of bacteria were isolated.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        The Effects of the Rountine Meatal Care with 10% Betadine on the Reduction of Catheter-Associated Urinary Tract Infection
        Journal of Korean Academy of Nursing. 1999;29(3):614-624.   Published online March 29, 2017
        Close
      • XML DownloadXML Download
      We recommend
      The Effects of the Rountine Meatal Care with 10% Betadine on the Reduction of Catheter-Associated Urinary Tract Infection
      The Effects of the Rountine Meatal Care with 10% Betadine on the Reduction of Catheter-Associated Urinary Tract Infection

      J Korean Acad Nurs : Journal of Korean Academy of Nursing
      Close layer
      TOP