Skip Navigation
Skip to contents

J Korean Acad Nurs : Journal of Korean Academy of Nursing

OPEN ACCESS

Articles

Page Path
HOME > J Korean Acad Nurs > Volume 36(6); 2006 > Article
Original Article
Comparison of Glass Particle Contamination according to Method of Ampule Cutting and Needle Aspiration
Jeong Sook Park, Hyae Ryeung Oh, Bo Hyae Seo, Jung Hee Bhang
Journal of Korean Academy of Nursing 2006;36(6):1033-1041.
DOI: https://doi.org/10.4040/jkan.2006.36.6.1033
Published online: March 28, 2017

1College of Nursing, Keimyung University, Korea.

jsp544@kmu.ac.kr

Copyright © 2006 Korean Society of Nursing Science

  • 8 Views
  • 0 Download
  • 3 Scopus
prev next
  • Purpose
    Glass particle contamination of the contents of single-dose glass ampules can occur upon opening. Different aspiration techniques, different sizes of needles, different sizes of ampules, and different cutting methods were studied to determine if they had any effect on glass particle contamination.
  • Method
    Different aspiration techniques(with filter, without filter), different sizes of needles(18G, 25G), different sizes of ampules(2ml, 20ml), and different cutting methods(with cotton, without cotton) were evaluated.
  • Method
    Twenty ampules were randomly assigned in each group. Three slides containing glass particles for each ampule were made and counted under a microscope by 3 study blind persons.
  • Result
    The number of glass particle contamination is much less when using a filter rather than without a filter. The number of glass particle contamination is much less when using a 25G needle rather than on 18G needle. The number of glass particle contamination is much less when using 2ml ampules rather than 20ml ampules. The number of glass particle contamination is much less when using cotton rather than without cotton.
  • Conclusion
    It was shown that using a filter, a small size needle, smaller sized ampules and using cotton when cutting the ampule will decrease the risk of parenteral injection of glass particles.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Comparison of Glass Particle Contamination according to Method of Ampule Cutting and Needle Aspiration
        Journal of Korean Academy of Nursing. 2006;36(6):1033-1041.   Published online March 28, 2017
        Close
      • XML DownloadXML Download
      We recommend
      Comparison of Glass Particle Contamination according to Method of Ampule Cutting and Needle Aspiration
      Comparison of Glass Particle Contamination according to Method of Ampule Cutting and Needle Aspiration

      J Korean Acad Nurs : Journal of Korean Academy of Nursing
      Close layer
      TOP